Symptoms
After updating Virtuozzo Hybrid Infrastructure to version 5.2 (5.2.0-135) the following false positive alerts may appear in the Admin panel:
- "Hypervisor host mismatch" alert may appear for shelved offload VMs
- "Volume attachment details mismatch" alert may appear for CDROM volumes and volumes with snapshots
For both situations there is no other errors or interruptions to the product functions, however the alert is still shown.
Cause
The issue is recognized as VSTOR-56639 and VSTOR-56640.
Resolution
The issue has been fixed in Virtuozzo Hybrid Infrastructure 5.2 Hotfix 1 (5.2.0-141) .